Location
Gagliano, Italia
Year / Duration
2012 · 2012
GAGLIANO GAS CENTER – IT SERVICE: Gasoline storage tank ENGINEERING SERVICES OFFERED: Process calculation verification General arrangement Construction drawings Installation drawings PROCESS DATA: Internal vapor space design pressure: 0.49 barg External tank design pressure: F.V. External vapor space design pressure: F.V. Operating pressure: atmospheric Design temperature min/max: 5/60 °C Operating temperature: ambient Fluid: gasoline Vapor space fluid: air Specific gravity of gasoline at 15°C: 736 kg/m³ EQUIPMENT: 1 steel storage tank (220-VA-101) Internal diameter of main body: 1,100 mm | Internal diameter of Jacket: 1,200 mm | Length (T.L.1 T.L): 1,850 mm